Wall Selection

 

 

R Values

STEP 1: Select the combination of structural products with the respective systems thermal resistance value:

WALL
SYSTEM

SP

HP

E5P

Exterior sheating

7/16"
Sheating

HP

EXCEL 1/2"

Interior
assembly

Poly/Gypsum

 

 

 

 

Exterior
air film

0.17

0.17

0.17

Exterior
cladding

0.43

0.43

0.43

Strapping/
air (brick)

0.96

0.96

0.96

Air barrier

0.06

0.06

0.06

Exterior
sheating

1.3

1.5

1.5

2X6 studs

7.15

7.15

7.15

Fiberglass

20

20

20

Interior
sheating

0

0

0

Vapour
barrier

0

0

0

Air
(strapping)

0

0

0

Gypsum

0.46

0.46

0.46

Interior
air film

0.68

0.68

0.68

 

 

 

 

R Nominal

24.06

24.26

24.26

R Frame

11.21

11.41

11.41

R Effective 16"

19.76

19.98

19.98

R Effective 24"

21.37

21.59

21.59

 

 

 

 

R "over stud"

4.06

4.26

4.26



WALL
SYSTEM

SE

HE

E5E

 

 

Exterior
sheating

7/16"
Sheating

H.P.

EXCEL 1/2"

Polystyrene
1 "

OSB 7/16"

Interior
assembly

ENERMAX

Poly/Gypsum

 

 

 

 

 

 

Exterior
air film

0.17

0.17

0.17

0.17

0.17

Exterior
cladding

0.43

0.43

0.43

0.43

0.43

Strapping/
air (brick)

0.96

0.96

0.96

0.96

0.96

Air barrier

0.06

0.06

0.06

0.06

0.06

Exterior
sheating

1.3

1.5

1.5

5

0.57

2X6 studs

7.15

7.15

7.15

7.15

7.15

Fiberglass

20

20

20

20

20

Interior
sheating

4.7

4.7

4.7

0

0

Vapour
barrier

0

0

0

0

0

Air
(strapping)

0

0

0

0

0

Gypsum

0.46

0.46

0.46

0.46

0.46

Interior
air film

0.68

0.68

0.68

0.68

0.68

 

 

 

 

 

 

R Nominal

28.76

28.96

28.96

27.76

23.33

R Frame

15.91

16.11

16.11

14.91

10.48

R Effective 16"

24.93

25.15

25.15

23.85

18.92

R Effective 24"

26.41

26.62

26.62

25.36

20.56

 

 

 

 

 

 

R "over stud"

8.76

8.96

8.76

7.76

3.33



Go on to STEP 2: Costs

 

 

  © Building Products of Canada Corp.   About the Site   Privacy Policies